     dot medical

External Pacemakers

Pace 300
External Triple Chamber Pacemaker

For more information Email: [email protected]
Click to download Pace 300 Brochure
Click if you are interested in other Osypka External Pacemakers

Pace 300

Triple Chamber

PACE 300

Special Features

  • Independent setting of AV and VV Delay
  • Stimulation impedance measurements in all channels
  • Automatic adjustment of A and V sensitivity
  • High output (18V) for safe pacing
  • "Pause" function for quick determination of heart function
  • Can be synchronised to Aortic Balloon Pump (requires BPI 202 accessory)
  • Programming structure similar to PACE 203H
  • Saving of most recent setting
  • Wall outlet power supply possible
The External Triple Chamber Pacemaker PACE 300 is designed for  cardiac resynchronisation therapy with one atrial and two independent ventricular channels. The available trigger modes and the adjustable interventricular stimulation delay provide a resynchronisation option for both ventricles. 
Dot Medical offers a range of External Pacemakers from Osypka for every kind of temporary cardiac stimulation environment. Triple Chamber when Cardiac Resynchronisation is important, Dual Chamber for standard post Cardiac Surgery and TAVI procedures, and Single Chamber for quick and easy simple pacing.

Technical Data

  • Modes: DDD (BV), DDD (LV), DDD (RV), VVI (BV), VVI (LV), VVI (RV), AAI, VDD (BV), VDD (RV), VDD (LV), DDT, DDI, DVI, DAI, DDD+AT, DAT, DOO, ODO, VVT, VOO, AAT, AOO, VDI, VAT
  • Basic rate 30-220 ppm
  • Maximum Tracking Rate (MTR) 80- 230 ppm
  • Overdrive Stimulation (atrial) 70-1000 ppm
  • Stimulation Amplitude 0.1 - 18V
  • Pulse Duration 0.05 - 1.5 ms
  • Sensitivity (atrial) 0.2- 20 mV, OFF
  • Sensitivity (ventricle) 1.0-20mV, OFF
  • Refractory Period (atrial) 250-400 ms
  • Refractory Period (ventricular) 250 ms
  • PVARP 100 - 500 ms
  • AV Delay 5-400 ms
  • VV Delay 5-80 ms 
  • Weight with battery 490 g

Technical Manuals and Resources

Click on the items below to access
  • PACE 300 Brochure
  • PACE 300 Technical Spec
  • PACE 300 Special Features
  • Other External Pacemakers


Osypka
Click on this button to connect with the Osypka Manufacturer website. 

Viewers of this page might also be interested in the following....

PACE 101H
Single Chamber Pacemaker PACE 101H
PACE 300
Dual Chamber Pacemaker PACE 203H
Picture
Temporary Pacing Wires
Picture
Temporary Pacing Cables

For all inquiries, call our Customer Service on 01625 668811